Air is forced through the drying tower, in it moisture and air contaminants are removed and a small amount of heated air (approx 200°C) is diverted downwards through the regeneration tower where it depressurizes the desiccant bed at a high temperature. Velocity is kept low so that air will be in contact with desiccant for some seconds. The cycle time of this process varies according to regeneration mass flow and temperature.
RANGE & Features
Capacity
230 cfm to 3,400 cfm
Pressure Dew point
-40° to -100°F
Initial cost
Low
Control
Auto
Space
Less space required
Maintenance Cost
Low
The air dryer package should be sized and selected to meet the peak system dry air demand for the facility (e.g. instrument air, feed air to nitrogen generator, plant air and process air).
Air dryers type that we offer
Features
Heated
Initial Cost
Moderate
Operating Cost
Moderately low
Maintenance Cost
Low
Dew point
-40° to -100°F dew point
Capacity
850 – 3,400 cfm
Purging
3.5% to 7%
Control
Microprocessor control
Operating voltage
250 Vtg 50Hz 1 phase